Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable

Chine 
                Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable
              fabrication et fournisseur

Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable image

Get Latest Price Request a quote

Info de Base.

N° de Modèle.
Power Cable

Fil Matériau du noyau
Bare fil de cuivre

Certificat
ISO, CCC

Modèle
YJLV22

Marque
royauté

taille populaire
50 mm, 95 mm, 120 mm, 150 mm

oem
oui

tension associée
0.6/1 kv, 8.7/15 kv, 12/20 kv, 21-35 kv, 36 kv

matériau armure
fil d′acier galvanisé, ruban d′acier, ruban de cuivre

écran
ruban en cuivre, fil de cuivre

standard
gb/t 12706-2008, cei 60502-2005

n° de noyau
1, 2, 3, 4, 5, 3+1, 4+1, 3+2

type d′entreprise
usine

couleur de la gaine
noir ou sur demande

Paquet de Transport
Steel-Wooden Drum or as Request

Spécifications
0.5-800mm2

Marque Déposée
Kingyear

Origine
Henan, China

Code SH
8544492100

Capacité de Production
500km/Month

Description de Produit

XLPE Insulated Copper Conductor PVC/XLPE Insulated Power Cable YJV /YJV22/ YJV32 Cable

Applications

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables.
XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.It can be applied in high temperature of 90 degree for a long time.

PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

Standard

IEC60502, BS6346, VDE, AS/NZS, UL, etc 

Specification

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1×4 2.3 0.7 1 0.8 1.8 10.9
1×6 2.8 0.7 1 0.8 1.8 11.4
1×10 3.6 0.7 1 0.8 1.8 12.2
1×16 4.5 0.7 1 0.8 1.8 13.1
1×25 5.6 0.9 1 0.8 1.8 14.6
1×35 6.7 0.9 1 1.25 1.8 16.6
1×50 8 1 1 1.25 1.8 18.1
1×70 9.4 1.1 1 1.25 1.8 19.7
1×95 11 1.1 1 1.6 1.8 22
1×120 12.4 1.2 1 1.6 1.8 23.6
1×150 13.8 1.4 1 1.6 1.8 25.4
1×185 15.3 1.6 1 1.6 1.8 27.4
1×240 17.5 1.7 1 1.6 1.9 29.9
1×300 19.5 1.8 1 2 2 33.1
1×400 22.6 2 1.2 2 2.2 37.3
1×500 25.2 2.2 1.2 2 2.3 40.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2×1.5 1.4 0.7 1 0.8 1.8 12.8
2×2.5 1.8 0.7 1 0.8 1.8 13.6
2×4 2.3 0.7 1 0.8 1.8 14.6
2×6 2.8 0.7 1 1.25 1.8 16.5
2×10 3.6 0.7 1 1.25 1.8 18.1
2×16 4.5 0.7 1 1.25 1.8 19.9
2×25 5.6 0.9 1 1.6 1.8 23.6
2×35 6.7 0.9 1 1.6 1.8 25.8
2×50 8 1 1 1.6 1.9 29
2×70 9.4 1.1 1 2 2 .3 3.2
2×95 11 1.1 1.2 2.1 3 7.1
2×120 12.4 1.2 1.2 2 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 20.6 49.9
2×240 17.5 1.7 1.4 2.5 20.7 55.1
2×300 19.5 1.8 1.6 2.5 20.9 60.2
2×400 22.6 2 1.6 2.5 30.1 67.7

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3×1.5 1.4 0.7 1 0.8 1.8 13.2
3×2.5 1.8 0.7 1 0.8 1.8 14.1
3×4 2.3 0.7 1 0.8 1.8 15.2
3×6 2.8 0.7 1 1.25 1.8 17.1
3×10 3.6 0.7 1 1.25 1.8 18.9
3×16 4.5 0.7 1 1.25 1.8 20.8
3×25 5.6 0.9 1 1.6 1.8 24.7
3×35 6.7 0.9 1 1.6 1.8 27.2
3×50 8 1 1 1.6 1.9 30.6
3×70 9.4 1.1 1 2 2.1 35.2
3×95 11 1.1 1.2 2 2.2 39.3
3×120 12.4 1.2 1.2 2 2.3 43
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3 64
3×400 22.6 2 1.6 3.15 3.3 73.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3



 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(« , »).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Qui nous sommes Chine Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.

Get Latest Price Request a quote

Popular Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable Des produits

  • No related articles
  • Popular kingyear Des produits

    Câble ABC moyenne tension au plafond câble ABC isolé pour treed Zone

    prix d'usine 0.6/1kv conducteur de cuivre ou aluminium isolation XLPE Câble d'alimentation électrique

    3X70 54,6 Câble en aluminium 16sqmm ABC ABC Liste de prix des câbles

    1kv grue à tour utilisés et à gaine PVC swa Armored Câble d'alimentation

    1050 Plaque en aluminium/aluminium/feuille plaque en aluminium de série 1000/feuille utilisée dans l'alimentation électrique de l'industrie chimique

    Basse tension kv 0.6/1ABC de l'antenne de frais généraux de câble Câble Câble avec isolation XLPE Bunded

    Popular Power Cable Des produits

    Manufacturer Price UL CSA Bx Mc Matel Clade Electric Power Control Cable Thhn Copper 600V 14/2 12/2 10/2 8/2

    0, 6/1 Kv Al Aluminum XLPE Insulation PVC PE Sheath Powers Cable Axmk Axpk 4X16 5X16 4X120 4X240

    UL CSA List Electric Power Urd Cable #1/0 AWG 15kv Rubber Epr 133% Cu Mv-105

    Al XLPE PVC Underground Cable 5X16mm2 0.6 /1kv

    Good Price UL Approval Armoured Cable 3/3 Mc Cable Copper with Ground

    Acwu90 Building Wire 3#1AWG 4#1AWG Construction Power Electric Cable CSA Listed

    Popular XLPE Insulated Power Cable Des produits

  • No related articles
  • Tags: , , ,

    SERVICE RAPIDE ET FIABLE POUR VOTRE PROJET

    Contactez nos experts qualifiés dès aujourd'hui pour trouver votre solution d'alimentation parfaite.

    POSER UNE QUESTION