ABC Conductors with XLPE Insulation Cable 3X95sqmm+1X50sqmm

Chine 
                ABC Conductors with XLPE Insulation Cable 3X95sqmm+1X50sqmm
              fabrication et fournisseur

ABC Conductors with XLPE Insulation Cable 3X95sqmm+1X50sqmm image

Get Latest Price Request a quote

Info de Base.

N° de Modèle.
ABC-IEC-ASTM-BS-NFC

Forme Matériel
Fil rond

Domaine d′application
Flame Retardant

Certificat
ISO9001, CE, CCC, OHSAS, TUV

Marque
Sanwu

abc
câble d′antenne

zone de coupe transversale
1.5 mm2

standard
cei, astm, bs, din, csa, etc

conducteur
aluminium/alliage d′aluminium/acsr

forme du conducteur
noyau circulaire ou noyau compact

type de conducteur
toronné

isolation
XLPE/PE/PVC

veste
pas de veste

expérience du fabricant
depuis 2006

Paquet de Transport
Packed as Rolls, or Wooden Drum

Spécifications
10-800mm2

Marque Déposée
SANWU CABLE

Origine
Luoyang, Henan, China

Code SH
8544492100

Capacité de Production
100, 000m/Day

Description de Produit

LUOYANG SANWU CABLE GROUP with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and trading, offering a diverse selection of quality wires and cables to industrial customers in more than 50 countries worldwide. The leading products are ACSR, Overhead ABC cables, Conductor, AAAC, AAC, power cable etc.

SANWU CABLE owns variously advanced equipment and large quantities of high skilled professionals. With complete management system, advanced production process, strict testing procedure and reliable product quality, we have successively got IS09001, IS014001,OHSAS18001,TUV Certificate, CCC(China Compulsory Certification), the national industrial production license and so on.
In terms of quality, it
 is highly controlled by our company to ensure that all the products we sell meet your requirements and give you reassurance with excellent after-sale service.In terms of service, we are focusing on your need, we concern what you concern and request what you request to provide a more satisfied service.

    Product Description

    ASTM BS CSA Standard Overhead Aluminium Conductor Aerial Bundle Cable

  ABC Cable Application
  This production is suitable for electric cable below 10KV AC, which will be mainly used for city power grid transmission line. It is simple structure, 

  safety and stable and is of good mechanism physical and electricity function. And also it has good function of proof track, creepage

  discharge, and air. Compared with naked wire, it has small gap so that can save wire route and decrease voltage drop. What is the 

  most important is that it will decrease the accident in power supplying and make people safe.

  Specific Property for ABC Cable

 1) the min. temperature of laying cable is not lower than 20°C.

 2) the Max. temperature of HDPE insulated cable is 150°C, and that of the XLPE insulated cable is   250°C when short circuit (5 seconds ).

 3) the Max. long-time working temperature of conductor of the HDPE insulated cable is 75°C,and that of the XLPE insulated cable is 90°C.

 4) every fault time of single-phase earth shall be less than one minute. And that also shall be less than 8 hours per time and be less than 125hours   every year.

 5) the permissible curving radius of single-core cable should be not less than 20(D±d) ±5%mm, and that of the multi-core cable should be not less   than 15(D±d) ±5%mm.

 ABC cable sketch structure as follows:

 Executive Standard:IEC   

Phas e Neutral Phas e Neutral

Approx. Overall Diam eter

Max. D.C.
Res is tance of Conductor at 20ºC
AAC+UV-XLPE AAAC Com pact Conductor UV-XLPE Ins ulation Conductor
No.X Norm al Cr os s
Section of Cores
No.X Norm al Cr os s
Section of Cores
No.of Al.Wire Overall Dia. Norm al Thick nes s Min. No./Dia. of Al Alloy Wire Phas e Neutral
No. X m m 2 No. X m m 2 m m m m Min. No./m m m m ohm /k m ohm /k m
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145

 

Phas e Neutral Phas e Neutral

Approx. Overall Diam eter

Max. D.C.
Res is tance of Conductor at 20ºC
AAC+UV-XLPE AAAC Com pact Conductor UV-XLPE Ins ulation Conductor
No.X Norm al Cr os s
Section of Cores
No.X Norm al Cr os s
Section of Cores
No.of Al.Wire Overall Dia. Norm al Thick nes s Min. No./Dia. of Al Alloy Wire Phas e Neutral
No. X m m 2 No. X m m 2 m m m m Min. No./m m m m ohm /k m ohm /k m
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145

 

Phase Neutral Service Connection Phase Neutral Service Connection Approx. Overall
Diameter of Bundled Cable
AAC+UV-XLPE AAAC+UV-XLPE AAC+UV-XLPE Conductor UV-XLPE Conductor UV-XLPE Compact Conductor UV-XLPE
No.X Normal Cross
Section of Cores
No.X Normal Cross
Section of Cores
No.X Normal Cross
Section of Cores
No. of Al. Wire Overall Dia. Normal No./Dia. of Al. Wire Normal No. of Al. Wire Overall Dia. Normal
Thickness Thickness Thickness
No. X mm2 No. X mm2 No. X mm2 mm mm mm mm No./mm mm mm mm
3 X 16 1 X 50 1 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 1 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 1 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 1 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 1 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 1 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 1 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
3 X 16 1 X 50 2 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 2 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 2 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 2 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 2 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 2 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 2 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2

 Executive Standard:ASTM

Code Word AWG or k cm il Bare neutral Mes s enger Phas e conductor Weight (k g/k m )
AAAC
s trading and w ires dia(m m )
Rated Strength
(lbs )
AAC
s trading and w ires dia(m m )
ins ulation thick nes s (m m )
Bay 3*6AWG+ 1*30.58 7/ 1.68 1110 1/4.11 1.14 207
French Coach 3*6AWG+ 1*30.58 7/ 1.68 1110 7/ 1.56 1.14 2 13
German Coach 3*4AWG+ 1*48.69 7/2. 12 1760 1/5.1 9 1.14 309
Arabian 3*4AWG+ 1*48.69 7/2. 12 1760 7/ 1.96 1.14 316
Belgian 3*2AWG+ 1*77.47 7/2.67 2800 7/2.47 1.14 476
Shet land 3*1/0AWG+ 1*123.3 7/3.37 4460 19/ 1.89 1.52 768
Thoroughbred 3*2/0AWG+ 1*155.4 7/3.78 5390 19/2.13 1.52 945
Trotter 3*2/0AWG+ 1*195.7 7/4.25 6790 19/2.39 1.52 1166
Walking 3*4/0AWG+ 1*246.9 7/4.77 8560 19/2.68 1.52 1442

Executive Standard:NFC

Des cr iption

Nom inal
cros s -s ection aera
Wire num ber in Conductor Max res is tance at 20 Average diam eter of
conductor
Rated Strength Average ins ulation thick nes s
m m 2 No. Ohm /k m Min(m m ) Max(m m ) KN m m

PHASE, NEUTRAL,
and PUBLIC HIGHTING

16 7 1.91 4.6 5.1 1.9 1.2
25 7 1.2 5.8 6.3   1.4
35 7 0.868 6.8 7.3   1.6
50 7 0.641 7.9 8.4   1.6
70 12 0.443 9.7 10.2   1.8
95 19 0.32 11 12   1.8
120 19 0.253 12 13.1   1.8
150 19 0.206 13.9 15   1.7
PORTER 54.6 7 0.63 9.2 9.6   1.6
70 7 0.5 10 10.2   1.5
95 19 0.343 12.2 12.9 27.5 1.6

Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997 (equivalent to IEC 60889:1987)
2) The zinc coated steel wire used for ACSR confirms to IEC 60888:1987
3) Production can be arranged according to customers’ requirement such as material standard etc.
4) We can also produce products according to the Standard of BS215, ASTM B232, and DIN48204.Technical characteristics

Certifications

ISO9001:2008, OHSAS, CCC, TUV Certifications.

Package&Shipping:

For Package: Support to pack as rolls, or with wooden drum or wooden steel drums. 

Shipment terms: 

By FOB, CFR or CIF by sea.

By DHL, UPS, Fedex express etc are also available.

Our Services

Luoyang Asian Sun Industrial Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Asian Sun attends International Exhibitions every year, we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) and solar pv cables etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.

1. Factory: 200,081 square meters, available for OEM;

2. Lead time: 5-7 working days after payment received;

3. Authentication: TUV, OHSAS, CCC, CQC, ISO9001:2008;

4. Payment terms: T/T, L/C, O/A;

5. Guarantee: 20 years;

6. QC inspection: Strict inspection before delivery;

After-sales Service:

1. All our cables will be tested well in production and before delivery.

2. Please contact us if any problem, we will respond within 24 hours.

Customers Visiting:

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(« , »).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Qui nous sommes Chine ABC Conductors with XLPE Insulation Cable 3X95sqmm+1X50sqmm fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.

Get Latest Price Request a quote

Popular ABC Câble Des produits

Mode Triplex Sevice Drop (ABC) Câble

Conducteur en aluminium personnalisé fourni de l'antenne câble isolé, ABC Câble.

Tous les conducteurs en aluminium 0.6/1kv isolation XLPE Câble ABC

ABC Câble recouvert de polyéthylène réticulé 1000V 4X16 4X25 4X35 4X50 4X70 4X95 Cabel d'alimentation en aluminium

0.6/1. Kv isolation PVC EN POLYÉTHYLÈNE RÉTICULÉ PE Les frais généraux de l'aluminium 4*35sqmm fil conducteur de câble pour câble de transmission de puissance ABC ligne

Câble électrique de l'antenne ABC délimitée 0.6/1kv (NFC 33-209)

Popular ABC Conductors with XLPE Insulation Cable 3X95sqmm+1X50sqmm Des produits

  • No related articles
  • Popular dycable Des produits

    Conducteur de chien ACSR/câble d'alimentation ACSR/AAC le fil électrique

    6AWG fil Dupliex Shepherd

    0.6/1kv Aluminiun échoués Core Câble antenne câble groupés ABC

    AAC tous les types de conducteurs en aluminium de 120 mm2 conducteurs électriques AAC

    TUV approuvé Câble solaire photovoltaïque (PV1-F 1*6.0mm2)

    Peso de distribution électrique de câble ACSR ACSR 1 0 /Câble standard IEC 61089

    Popular XLPE Insulated Aerial Bundled Cable Des produits

  • No related articles
  • Tags: , , ,

    SERVICE RAPIDE ET FIABLE POUR VOTRE PROJET

    Contactez nos experts qualifiés dès aujourd'hui pour trouver votre solution d'alimentation parfaite.

    POSER UNE QUESTION