Aluminum Conductor Steel Reinforced Stranded Conductor 16mm2 All Aluminum Alloy Bare AAAC Conductor

Chine 
                Aluminum Conductor Steel Reinforced Stranded Conductor 16mm2 All Aluminum Alloy Bare AAAC Conductor
              fabrication et fournisseur

Aluminum Conductor Steel Reinforced Stranded Conductor 16mm2 All Aluminum Alloy Bare AAAC Conductor image

Get Latest Price Request a quote

Info de Base.

N° de Modèle.
Bare conductor

Fil Matériau du noyau
aluminium

Certificat
ISO, CCC, bv, sgs

Modèle
toronné

standard
astm, bs, cei, nfc, csa

avantages
haute qualité, prix compétitif, réponse rapide

n° de noyau
7-91

tension associée
0.6/1 kv, 8.7/15 kv, 12-20 kv, 21/35 kv

conditions d′expédition
fob, cfr, cif

exporter l′expérience
asie du sud-est, afrique, moyen-orient

oem/odm
oui

délai de livraison
15 à 30 jours

exemple
gratuit

Paquet de Transport
Wooden Drum, Steel-Wooden Drum or as Requirement

Spécifications
10mm2-1500mm2

Origine
Henan, China

Code SH
7614900000

Capacité de Production
1000 Tons Each Month

Description de Produit

Applications

AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.

Standard
 BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008

Specification
Physical contents of aluminum alloy :- 
1. Resistivity – 0.0326 Ohms mm2/m at 20°C 
2. Density – 2.70 kgm/dm3 at 20°C 
3. Coefficient of Linear Expansion – 23 x 10-6 / °C 
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C 
5. Material – Heat treated Al. Mg. Si. Alloy 
– Approximately 0.5% Mg & 0.5% Si 
 
ASTM B399

Code Name Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load
Nominal Actual
MCM mm2 AWG or MCM Al/Steel mm mm kg/km kN
Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92
Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84
Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45
Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97
Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93
Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18
Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05
Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76
Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91
Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48
Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52
Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42
Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21
Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47

 
IEC 61089
Code Number A2 Conductor A3 Conductor  Max.D.C. Resistance of Conductor at 20ºC
Number of Wires  Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires  Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² mm mm kg/km daN mm mm kg/km daN Ω/km
16 7 1.83 5.49 50.4 5.43 7 1.84 5.52 50.8 6.04 1.7896
25 7 2.29 6.87 78.7 8.49 7 2.30 6.9 79.5 9.44 1.1453
40 7 2.89 8.67 125.9 13.58 7 2.91 8.73 127.1 15.1 0.7158
63 7 3.63 10.8 198.3 21.39 7 3.65 10.95 200.2 23.06 0.4545
100 19 2.78 13.9 316.3 33.95 19 2.79 13.95 319.3 37.76 0.2877
125 19 3.10 15.5 395.4 42.44 19 3.12 15.6 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 19 3.53 17.65 511.0 58.56 0.1798
200 19 3.93 19.65 623.7 67.91 19 3.95 19.75 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 19 4.41 22.05 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 37 3.55 24.85 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 37 4.0 28 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 37 4.24 29.68 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 37 4.47 31.29 1600.6 183.oo 0.0577
560 61 3.67 33.03 1778.4 190.14 61 3.69 33.21 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 61 3.91 35.19 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 61 4.15 37.35 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 61 4.4 39.6 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 91 3.83 42.13 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 91 4.03 44.33 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 91 4.27 46.97 3594.4 409.92 0 0258
1250 91 4.49 49.39 3973.7 424.41    

 
BS EN50183
Code Name  Calculated
Cross Section
No..Dia.of Wires  Overall Diameter Weight Rated Strength
  mm² No./mm mm kg/km kN
Box 18.8 7/1.85 5.55 51.4 5.55
Acacia 23.8 7/2.08 6.24 64.9 7.02
Almond 30.1 7/2.34 7.02 82.2 8.88
Cedar 35.5 7/2.54 7.62 96.8 10.46
Deodar 42.2 7/2.77 8.31 115.2 12.44
Fir 47.8 7/2.95 8.85 130.6 14.11
Hazel 59.9 7/3.30 9.90 163.4 17.66
Pine 71.6 7/3.61 10.8 195.6 21.14
Holly 84.1 7/3.91 11.7 229.5 24.79
Willow 89.7 7/4.04 12.1 245,0 26.47
Oak 118.9 7/4.65 14.0 324.5 35.07
Mulberry 150.9 19/3.18 15.9 414.3 44.52
Ash 180.7 19/3.48 17.4 496.1 53.31
Elm 211.0 19/3.76 18.8 579.2 62.24
Poplar 239.4 37/2.87 20.1 659.4 70.61
Sycamore 303.2 37/3.23 22.6 835.2 89.40
Upas 362.1 37/3.53 24.7 997.5 106.82
Yew 479.0 37/4.06 28.4 1319.6 141.31
Totara 498.1 37/4.14 29.0 1372.1 146.93
Rubus 586.9 61/3.50 31.5 1622.0 173.13
Sorbus 659.4 61/3.71 33.4 1822.5 194.53
Araucaria 821.1 61/4.14 37.3 2269.4 242.24
Redwood 996.2 61/4.56 41.0 2753.2 293.88

 
Din 48201
Code number Calculated area Number of wires Diameter of wire Overall diameter of conductor Linear mass Rated tensile strength Max. DC resistance at 20ºC
mm2 mm2   mm mm kg/km daN Ω/km
16 15.89 7 1.70 5.1 43 444 2.0910
25 24.25 7 2.10 6.3 66 677 1.3703
35 34.36 7 2.50 7.5 94 960 0.9669
50 49.48 7 3.00 9.0 135 1382 0.6714
50 48.35 19 1.80 9.0 133 1350 0.6905
70 65.81 19 2.10 10.5 181 1838 0.5073
95 93.27 19 2.50 12.5 256 2605 0.3579
120 116.99 19 2.80 14.0 322 3268 0.2854
150 147.11 37 2.25 15.8 406 4109 0.2274
185 181.62 37 2.50 17.5 500 5073 0.1842
240 242.54 61 2.25 20.3 670 6774 0.1383
300 299.43 61 2.50 22.5 827 8363 0.1120
400 400.14 61 2.89 26.0 1104 11176 0.0838
500 499.63 61 3.23 29.1 1379 13960 0.06709
625 626.20 91 2.96 32.6 1732 17490 0.0540
800 802.09 91 3.35 36.9 2218 22402 0.0418
1000 999.71 91 3.74 41.1 2767 27922 0.0335

Specification

Stranded 1350 aluminum conductors shown in this section of data are classified, as follows: 

Class AA  For bare conductors usually used in overhead lines.
Class A  For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required.
Class B  For conductors to be insulated with various materials and for conductors indicated under Class A where greater flexibility is required. 
Class C  For conductors where greater flexibility is required

Refered Standards
(1). IEC 61089: Round wire concentric lay overhead electrical stranded conductors
(2). DIN 48 201-5: All Aluminium Conductors
(3). BS 215-1: Aluminium strander conductors
(4). ASTM B231: Stranded Specification for Concentric-Lay-Stranded Aluminium 1350 Conductors
(5). AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 

Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8) aluminum conductor steel supported (ACSS)
(9) aluminum conductor carbon core(ACCC)

About Us

Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees’ number has exceeded 200.

We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.

We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

Our mainly products as follow: 
1–pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2–pvc and xlpe insulated power cable with or without armor upto 35kv.
3–rubber cable like welding cable, mine cable, EPR cable and so on.
4–aerial bundled cable(ABC cable) up to 10kv.
5–bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.

Packing & Delivery
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.

Certification
We have obtained CCC, ISO9001, ISO14001 certificates, passed the SGS and BV test.

Our Service
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

Test

FAQ
Q:I didn’t find the cable which I need in this page?
A:If you didn’t find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What’s your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What’s your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.

Welcome your inquiry! Any question please feel free to contact me as follows:
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(« , »).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Qui nous sommes Chine Aluminum Conductor Steel Reinforced Stranded Conductor 16mm2 All Aluminum Alloy Bare AAAC Conductor fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.

Get Latest Price Request a quote

Popular AAAC Des produits

Conducteur entièrement en aluminium de 150 mm2 AAC ASTM multibrins

AAAC (tous les conducteurs en alliage aluminium) pour les frais généraux Ligne de transmission

Rose, Iris, Aster, Dahlia, gui, Coreopsis ASTM B231 Câble conducteur tout en aluminium nu75.5 mm Almelec 1X2 conducteur de l′Aster

AAAC ACSR AAC Acar Conducteurs multibrins en aluminium multicoeur

Tous les conducteurs multibrins en alliage aluminium AAAC 6201 Conductor

AAAC Conducteur câble conducteur Cable-All alliage en aluminium

Popular Aluminum Alloy Cable Des produits

  • No related articles
  • Popular Aluminum Conductor Steel Reinforced Stranded Conductor 16mm2 All Aluminum Alloy Bare AAAC Conductor Des produits

  • No related articles
  • Popular kingyear Des produits

    Diverses Spécifications bobines en aluminium/aluminium laminage en alliage

    15kv 3c*120mm2 isolés en polyéthylène réticulé swa gainé PVC blindés Câble d'alimentation souterraine Yjlv Yjv3232

    7core Résistance à la chaleur de câble en caoutchouc de silicone 16AWG 22AWG du câble à gaine en caoutchouc à usage général

    1272kcmil/MCM conducteurs (Al ACSR Butor 45/4.27 + St 7/2.85mm)

    AAC Hard-Drawn 500mm Câble Câble conducteur nu tout en aluminium

    Câble de câble de descente service ABC Collie Câble isolé de frais généraux

    Tags: , , ,

    SERVICE RAPIDE ET FIABLE POUR VOTRE PROJET

    Contactez nos experts qualifiés dès aujourd'hui pour trouver votre solution d'alimentation parfaite.

    POSER UNE QUESTION