Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable

Chine 
                Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable
              fabrication et fournisseur

Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable image

Get Latest Price Request a quote

Info de Base.

N° de Modèle.
Power Cable

Fil Matériau du noyau
Bare fil de cuivre

Certificat
ISO, CCC

Modèle
YJLV22

Marque
royauté

taille populaire
50 mm, 95 mm, 120 mm, 150 mm

oem
oui

tension associée
0.6/1 kv, 8.7/15 kv, 12/20 kv, 21-35 kv, 36 kv

matériau armure
fil d′acier galvanisé, ruban d′acier, ruban de cuivre

écran
ruban en cuivre, fil de cuivre

standard
gb/t 12706-2008, cei 60502-2005

n° de noyau
1, 2, 3, 4, 5, 3+1, 4+1, 3+2

type d′entreprise
usine

couleur de la gaine
noir ou sur demande

Paquet de Transport
Steel-Wooden Drum or as Request

Spécifications
0.5-800mm2

Marque Déposée
Kingyear

Origine
Henan, China

Code SH
8544492100

Capacité de Production
500km/Month

Description de Produit

XLPE Insulated Copper Conductor PVC/XLPE Insulated Power Cable YJV /YJV22/ YJV32 Cable

Applications

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables.
XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.It can be applied in high temperature of 90 degree for a long time.

PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

Standard

IEC60502, BS6346, VDE, AS/NZS, UL, etc 

Specification

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1×4 2.3 0.7 1 0.8 1.8 10.9
1×6 2.8 0.7 1 0.8 1.8 11.4
1×10 3.6 0.7 1 0.8 1.8 12.2
1×16 4.5 0.7 1 0.8 1.8 13.1
1×25 5.6 0.9 1 0.8 1.8 14.6
1×35 6.7 0.9 1 1.25 1.8 16.6
1×50 8 1 1 1.25 1.8 18.1
1×70 9.4 1.1 1 1.25 1.8 19.7
1×95 11 1.1 1 1.6 1.8 22
1×120 12.4 1.2 1 1.6 1.8 23.6
1×150 13.8 1.4 1 1.6 1.8 25.4
1×185 15.3 1.6 1 1.6 1.8 27.4
1×240 17.5 1.7 1 1.6 1.9 29.9
1×300 19.5 1.8 1 2 2 33.1
1×400 22.6 2 1.2 2 2.2 37.3
1×500 25.2 2.2 1.2 2 2.3 40.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2×1.5 1.4 0.7 1 0.8 1.8 12.8
2×2.5 1.8 0.7 1 0.8 1.8 13.6
2×4 2.3 0.7 1 0.8 1.8 14.6
2×6 2.8 0.7 1 1.25 1.8 16.5
2×10 3.6 0.7 1 1.25 1.8 18.1
2×16 4.5 0.7 1 1.25 1.8 19.9
2×25 5.6 0.9 1 1.6 1.8 23.6
2×35 6.7 0.9 1 1.6 1.8 25.8
2×50 8 1 1 1.6 1.9 29
2×70 9.4 1.1 1 2 2 .3 3.2
2×95 11 1.1 1.2 2.1 3 7.1
2×120 12.4 1.2 1.2 2 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 20.6 49.9
2×240 17.5 1.7 1.4 2.5 20.7 55.1
2×300 19.5 1.8 1.6 2.5 20.9 60.2
2×400 22.6 2 1.6 2.5 30.1 67.7

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3×1.5 1.4 0.7 1 0.8 1.8 13.2
3×2.5 1.8 0.7 1 0.8 1.8 14.1
3×4 2.3 0.7 1 0.8 1.8 15.2
3×6 2.8 0.7 1 1.25 1.8 17.1
3×10 3.6 0.7 1 1.25 1.8 18.9
3×16 4.5 0.7 1 1.25 1.8 20.8
3×25 5.6 0.9 1 1.6 1.8 24.7
3×35 6.7 0.9 1 1.6 1.8 27.2
3×50 8 1 1 1.6 1.9 30.6
3×70 9.4 1.1 1 2 2.1 35.2
3×95 11 1.1 1.2 2 2.2 39.3
3×120 12.4 1.2 1.2 2 2.3 43
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3 64
3×400 22.6 2 1.6 3.15 3.3 73.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3



 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(« , »).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Qui nous sommes Chine Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.

Get Latest Price Request a quote

Popular Conductor PVC/XLPE Insulated Power Cable Yjv /Yjv22/ Yjv32 Cable Des produits

  • No related articles
  • Popular kingyear Des produits

    Câble d'alimentation électrique XLPE en cuivre à 4 conducteurs, alimentation électrique de 0,75 mm Câble électrique

    Un5052 A3003 A1060 A1050 en alliage de bobine en aluminium de haute qualité

    3X1.5 3X2.5 3X4 3X6 4X1.5 5X10 Sq mm XLPE isolé Câble d′alimentation

    450/750V Faible tension du fil de cuivre électrique PVC Bâtiment Zr-BV/BVV//BVR/RV/RVV Kabel fil

    1.5Mm 2.5mm 4mm de 6mm 10mm cuivre simple coeur de PVC et de câbles électriques de câblage de la Chambre Prix de fil Le fil de bâtiment

    16AWG 16mm 061kv 5 conducteurs en PVC souple de coeurs sur le fil blindé de matières premières pour câble d'alimentation

    Popular Power Cable Des produits

    Yjv 300mm2 16 Sqmm 1 4 Core XLPE Insulated PVC Sheathed Armoured Aluminum Power Cable

    11kv 600V 185mm 4 Core XLPE Armoured Cable 16mm2 Specification Price South Africa

    N2xs FL 2y 1X500/50 20 Kv Meidum Voltage Cable with Good Price

    35 Sq mm 4 Core 23kv Medium Voltage PVC Copper Armoured Garden Cable Price Manufactur

    Manufacturer Price UL CSA Bx Mc Matel Clade Electric Power Control Cable Thhn Copper 600V 14/2 12/2 10/2 8/2

    8.7/15 Kv Underground Power Cable Armoured Copper Conductor XLPE Insulation PVC Jacket 95mm 3 Core

    Popular XLPE Insulated Power Cable Des produits

  • No related articles
  • Tags: , , ,

    SERVICE RAPIDE ET FIABLE POUR VOTRE PROJET

    Contactez nos experts qualifiés dès aujourd'hui pour trouver votre solution d'alimentation parfaite.

    POSER UNE QUESTION