1. Applications
Conductor(AAC, AAAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Service Performance
(1). The permissible long-time operating temperature for aerial conductor is 70oC.
(2). Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3). When connecting conductors, the conductor beside the connecting tube cant be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are install, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4). Under installaion, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.
3. Product Performance
(1). The electrical performance of AAC and ACSR is indicated in DCΩ /km(20oC). The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 nΩ . M of international standard value.
(2). The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min. Tensile of corresponding size specified in the standard for aluminum wire.
(3). The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.
A. The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min. Tensile strength of corresponding size specified in the standard for aluminum wire.
B. The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.
4. Material Standard
(1). The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889: 1987).
(2). The zinc coated steel wire used for ACSR conforms to IEC 60888: 1987.
(3). Production can be arranged according to customers requirements for material standard, etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
| Code name | Aluminum Area |
Stranding& Wire Diameter |
Approx Overall Diameter |
Approx Weight |
Breaking Load |
DC Resistance |
||
| Al | Steel | |||||||
| AWG | mm 2 | No./mm | No./mm | mm | Kg/km | KN | Ohm/km | |
| Turkey | 6 | 13.30 | 6/1.68 | 1/1.68 | 5.04 | 53.75 | 5303 | 2.157 |
| Swan | 4 | 21.18 | 6/2.12 | 1/2.12 | 6.36 | 85.57 | 8302 | 1335 |
| Swanate | 4 | 21.12 | 7/1.96 | 1/2.61 | 6.53 | 99.56 | 10642 | 1352 |
| Sparrow | 2 | 33.59 | 6/2.67 | 1/2.67 | 8.01 | 135.70 | 12653 | 0.854 |
| Raven | 1/0 | 53.52 | 6/3.37 | 1/3.37 | 10.10 | 216.20 | 19455 | 0.536 |
| Quail | 2/0 | 67.32 | 6/3.78 | 1/3.78 | 11.30 | 272.00 | 23529 | 0.426 |
| Pigeon | 3/0 | 85.14 | 6/4.25 | 1/4.25 | 12.80 | 344.00 | 29417 | 0.337 |
| Penguin | 4/0 | 107.20 | 6/4.77 | 1/4.77 | 14.30 | 433.40 | 37055 | 0.268 |
| Waxwing | 266800 | 135.00 | 18/3.09 | 1/3.09 | 15.50 | 430.50 | 30519 | 0.213 |
| Merlin | 336400 | 170.20 | 18/3.47 | 1/3.47 | 17.40 | 542.90 | 38487 | 0.169 |
| Linnet | 336400 | 170.60 | 26/2.89 | 7/2.25 | 18.30 | 689.90 | 62918 | 0.169 |
| Hawk | 477000 | 241.6 | 26/3.44 | 7/2.67 | 21.80 | 975.50 | 86011 | 0.120 |
| Dove | 556500 | 282.6 | 26/3.72 | 7/2.89 | 23.6 | 1142.00 | 100838 | 0.1030 |
| Peacock | 605000 | 306.2 | 24/4.03 | 7/2.69 | 24.2 | 1159.00 | 95861 | 0.0948 |
| Drake | 795000 | 402.5 | 26/4.44 | 7/3.45 | 28.1 | 1626.00 | 138669 | 0.0717 |
| Rail | 954000 | 483.8 | 45/3.70 | 7/2.47 | 29.6 | 1602.00 | 115626 | 0.0597 |
| AAAC Technical Characters Based on Standard BS EN50182 | ||||||||
| BS EN50182 | ||||||||
| Code | Old Code | Cross section | No. of wires | Diameter | Mass per unit length | Rated strength | DC resistance at 20 | |
| Wire | Conductor | |||||||
| mm2 | mm | mm | kg/km | KN | Ω/km | |||
| 19-Al3 | BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
| 24-Al3 | ACACIA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
| 30-Al3 | ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
| 35-Al3 | CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
| 42-Al3 | DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
| 48-Al3 | FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
| 60-Al3 | HAZEL | 59.9 | 7 | 3.30 | 9.90 | 163.4 | 17.66 | 0.5494 |
| 72-Al3 | PINE | 71.6 | 7 | 3.61 | 10.80 | 195.6 | 21.14 | 0.4591 |
| 84-Al3 | HOLLY | 84.1 | 7 | 3.91 | 11.70 | 229.5 | 24.79 | 0.3913 |
| 90-Al3 | WILLOW | 89.7 | 7 | 4.04 | 12.10 | 245.0 | 26.47 | 0.3665 |
| 119-Al3 | OAK | 118.9 | 7 | 4.65 | 14.00 | 324.5 | 35.07 | 0.2767 |
| 151-Al3 | MULBERRY | 150.9 | 19 | 3.18 | 15.90 | 414.3 | 44.52 | 0.2192 |
| 181-Al3 | ASH | 180.7 | 19 | 3.48 | 17.40 | 496.1 | 53.31 | 0.1830 |
| 211-Al3 | ELM | 211.0 | 19 | 3.76 | 18.80 | 579.2 | 62.24 | 0.1568 |
| 239-Al3 | POPLAR | 239.4 | 37 | 2.87 | 20.10 | 659.4 | 70.61 | 0.1387 |
| 303-Al3 | SYCAMORE | 303.2 | 37 | 3.23 | 22.60 | 835.2 | 89.40 | 0.1095 |
| 362-Al3 | UPAS | 362.1 | 37 | 3.53 | 24.70 | 997.5 | 106.82 | 0.0917 |
| 479-Al3 | YEW | 479.0 | 37 | 4.06 | 28.40 | 1319.6 | 141.31 | 0.0693 |
| 498-Al3 | TOTARA | 498.1 | 37 | 4.14 | 29.00 | 1372.1 | 146.93 | 0.0666 |
| 587-Al3 | RUBUS | 586.9 | 61 | 3.50 | 31.50 | 1622.0 | 173.13 | 0.0567 |
| 659-Al3 | SORBUS | 659.4 | 61 | 3.71 | 33.40 | 1822.5 | 194.53 | 0.0505 |
| 821-Al3 | ARAUCARIA | 821.1 | 61 | 4.14 | 37.30 | 2269.4 | 242.24 | 0.0406 |
| 996-Al3 | REDWOOD | 996.2 | 61 | 4.56 | 41.00 | 2753.2 | 293.88 | 0 |
Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.
We have been engaged in producing electric cable and wire for nearly 20 years, and we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .
Our product range is as following:
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
*Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
* PVC insulated wire (Rated voltage to 450/750V)
*THHN/THWN wire
*PVC insulated Power Cable
*XLPE insulated Power Cable
*Rubber sheathed Cable
*Control Cable
*Welding Cable
*Cable Accessories
We take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer’s factory in Zhengzhou ,China .
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.
2.What are your main products?
- Electrical wire/PVC Building Wires.
- PVC/XLPE insulated Power Cables up to 110kv.
- Overhead Aerial Bundle Cable/ABC Cables.
- Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
- Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
- Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
- Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s’ Conductor.
4.Is the quality of your products guaranteed?
5.Which markets do you involve mainly in?
6. What is your payment term?
Welcome your kind enquiry!
/* March 5, 2024 10:24:42 */
!function(){function s(e,r){var a,o={};try{e&&e.split(« , »).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Qui nous sommes Chine High Tensile ASTM Standard Overhead AAAC Conductor Cable fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.
Get Latest Price Request a quote
Popular AAAC Des produits
AAAC, ACSR, AAC Conducteurs multibrins en aluminium ACSR dimensions de conducteur.
AAC/AAAC/ACSR/sacr/conducteur dénudé de frais généraux de l'ACCC
La norme BS 40mcm AAAC conducteur conducteur groupés avec de la graisse d'antenne
Type AAAC 6201 Darien 559.5MCM 283.7mm2 tous conducteurs en alliage d'aluminium
AAAC 240mm2 conducteurs nus 48201 Frais généraux de la norme DIN
ACSR, AAC, AAAC, conducteurs Aacsr
Popular Acar Des produits
Frais généraux de Haute tension conducteur nu Acar
ACAR 1200 MCM conducteurs en alliage aluminium pour 500 kV de ligne de transmission
Acar conducteurs renforcé en alliage en aluminium
AAC, AAAC, Acar, ACSR/AW, l'ACCC, ACSR Conductor
Les lignes de transmission de puissance AAC AAAC ACSR Aacsr Acar ACS AC Al conducteur nu
Ligne de conducteur en aluminium nu ACSR, AAAC, AAC, Acar
Popular High Tensile ASTM Standard Overhead AAAC Conductor Cable Des produits
Popular jsgroup Des produits
Câble cuivre conducteur de la DPA SPT 2*12AWG
Conducteur en cuivre flexible en caoutchouc du câble de soudage électrique isolé
Conducteurs nus de transmission de charge conducteurs AAC/AAAC/ACSR conducteurs en aluminium
La norme IEC 2X2.5MM2 Câble de jumeaux
Conducteur d′isolation en cuivre XLPE câble blindé blindé flexible de puissance en PVC
Tags: AAAC, Acar, High Tensile ASTM Standard Overhead AAAC Conductor Cable, jsgroup