Na2xs (Fl) 2Y 1X400/50 12/20 Kv câble HDPE d′étanchéité longitudinale

Chine 
                Na2xs (Fl) 2Y 1X400/50 12/20 Kv câble HDPE d′étanchéité longitudinale
              fabrication et fournisseur

Na2xs (Fl) 2Y 1X400/50 12/20 Kv câble HDPE d′étanchéité longitudinale image

Get Latest Price Request a quote

Info de Base.

N° de Modèle.
NA2XS(FL)2Y 1×400/50 12/20 kV

Fil Matériau du noyau
Aluminum

Certificat
ISO, CCC, CE, RoHS

Modèle
Na2xs(FL)2y

Marque
Hongda

Armour
Non

Conductor Material
Copper/Aluminum

Standard
VDE 0482-332-1-2, DIN En 60332-1-2 / IEC 60332-1

Quality Guarantee
Ten Years

Core
1core/Three Cores

Insulated Color
as Your Requirement

Sheath Color
Black

Screen
Copper Wires

Manufacture
Yes

Paquet de Transport
Wooden Drum

Spécifications
12/20 KV 1X95/50mm2

Marque Déposée
Hongda

Origine
China, Henan

Code SH
8544492100

Capacité de Production
1000km/Per Months

Description de Produit

Câble d'alimentation de tension moyenne européenne : NA2XSY/N2XSY    6/10, 12/20 kV, kV de 18/30 kV

 

L'application  

Adapté pour une installation principalement dans les stations d'alimentation, à l'intérieur et dans des gaines de câble, à l'extérieur, le métro et dans l'eau ainsi que pour l'installation sur les chemins de câbles pour les industries, l'interrupteur de conseils et de stations d'alimentation. En raison de la bonne caractéristique de ponte, ce câble peut également être installés dans des conditions difficiles dans de difficiles guide de ligne façons.
L'intérieur de la conduite de couche entre le conducteur et de l'isolation en polyéthylène réticulé et de la couche conductrice extérieur collé fermement sur la construction d'isolation en polyéthylène réticulé assure une libre de décharges partielles avec une haute fiabilité opérationnelle.

Les données techniques European  
  • Les câbles de puissance à isolation en polyéthylène réticulé à la norme DIN VDE 0276 partie 620, HD 620 S1 et IEC 60502
  • Plage de température
    Pendant l'installation jusqu'à -5°C/+23 °F
  • La température de fonctionnement
    Max. +90°C/+194 °F
  • Court-circuit +250°C de température/+482 °F
    (Court-circuit durée jusqu'à 5 sec.)
  • Tension nominale
    U0/U 6/10, 12/20 kV, kV de 18/30 kV
  • Tensions de fonctionnement pour
    6/10 kV = max. 12 kV
    12/20 kV = max. 24 kV
    18/30 kV = max. 36 kV
  • Les tensions de test pour
    6/10 kV = 15 kV
    12/20 kV = 30 kV
    18/30 kV = 45 kV
  • Rayon de courbure minimal
    Pendant l'installation max. 15x Ø câble
  • Valeurs nominales de puissance table
    Voir l'Information technique
Pour les câbles de puissance avec Code-Designation PVC ou de l'isolant en polyéthylène réticulé
La conception Identification de la conception   Explications
Conductor N Selon la norme VDE
(Aucune abréviation pour conducteur de cuivre)
Un Les conducteurs en aluminium
Y L'isolement de thermoplastique, chlorure de polyvinyle (PVC)
2X L'isolement polyéthylène réticulé (XLPE)
Conducteur concentrique, blindage   C Conducteurs concentriques de fils de cuivre et cuivre, de bande hélicoïdale blessés
CW Conducteurs concentriques de fils de cuivre dans la vague conal formation et de ruban de cuivre et de blessés, hélicoïdale
CE Conducteurs concentriques de fils de cuivre et de ruban de cuivre sur chaque conducteur, hélicoïdale blessés
Le blindage S Blindage de fils de cuivre et cuivre, de bande hélicoïdale blessés
SE Le blindage de fils de cuivre et de ruban de cuivre sur chaque conducteur, hélicoïdale blessés
(F) La preuve à l'eau blindage longitudinalement
Armor B Armure de bande en acier
F Armure de fils plats en acier galvanisé
G Compteur de bande en acier galvanisé helix
Veste K Veste de plomb
Gaine extérieure   Y Gaine en PVC
2Y Veste de PE
Câble pour U0/U 0.6/1 kV sont en outre désigné avec
  -J Les câbles avec vert-jaune-vert (naturel) conducteur sont marqués avec conducteur de protection
-O Câbles sans vert-jaune-vert (naturel) sont marqués de conducteur sans conducteur de protection

 

La construction du câble  
  • La circulaire en aluminium nu-conducteur de fils toronnés à HD 383
  • L'intérieur revêtement semi-conductrice
  • Isolation des conducteurs de polyéthylène réticulé (XLPE), le PE-composé dix8 à 620.1 HD
  • Extrusion de extérieur revêtement semi-conductrice epissure avec l'isolement
  • Enroulement du matériau conducteur
  • Blindage : le tressage de fils de cuivre avec un ou deux bandes application hélicoïdale
  • L'enrubannage
  • Gaine extérieure en PVC, le composé DMV6 à 620.1 HD
  • Veste couleur : rouge

 

La tension nominale  
 
6/10 kV
 
12/20 kV
 
18/30 kV
Description & No conducteurs x cross-sec. mm2, Tension nominale Tension de fonctionnement max. Isolée. D'ÉPAISSEUR-ness mm Veste-ness mm épais Extérieur
Dia. min.-max.
Poids de cuivre
Kg/km
Alu Poids kg/km Poids env. kg/km AWG
NA2XSY 6/10kV 1×50 rm/16 12 3.4 2.5 24,0 – 29,0 182.0 145,0 780.0 1
NA2XSY 6/10kV 1×70 rm/16 12 3.4 2.5 26,0 – 31,0 182.0 203.0 875.0 2/0
NA2XSY 6/10kV 1×95 rm/16 12 3.4 2.5 27,0 – 32,0 182.0 276,0 990.0 3/0
NA2XSY 6/10kV 1×120 RM/16 12 3.4 2.5 29,0 – 34,0 182.0 348.0 1110.0 4/0
NA2XSY 6/10kV 1×150 RM/16 12 3.4 2.5 30,0 – 35,0 182.0 435.0 1240.0 300 kcmil
NA2XSY 6/10kV 1×150 RM/25 12 3.4 2.5 30,0 – 35,0 283.0 435.0 1310.0 300 kcmil
NA2XSY 6/10kV 1×185 RM/25 12 3.4 2.5 32,0 – 37,0 283.0 537.0 1460.0 350 kcmil
NA2XSY 6/10kV 1×185 RM/16 12 3.4 2.5 32,0 – 37,0 182.0 537.0 1405.0 350 kcmil
NA2XSY 6/10kV 1×240 RM/25 12 3.4 2.5 34,0 – 39,0 283.0 696.0 1660.0 500 kcmil
NA2XSY 6/10kV 1×240 RM/16 12 3.4 2.5 34,0 – 39,0 182.0 696.0 1615.0 500 kcmil
NA2XSY 6/10kV 1×300 RM/25 12 3.4 2.5 36,0 – 41,0 283.0 870,0 1910.0 600 kcmil
NA2XSY 6/10kV 1×400 RM/35 12 3.4 2.5 40,0 – 45,0 394,0 1160.0 2315.0 750 kcmil
NA2XSY 6/10kV 1×500 RM/35 12 3.4 2.5 43,0 – 48,0 394,0 1450.0 2750.0 1000 kcmil
 
NA2XSY 12/20kV 1×50 rm/16 24 5.5 2.5 28,0 – 33,0 182.0 145,0 950.0 1
NA2XSY 12/20kV 1×70 rm/16 24 5.5 2.5 30,0 – 35,0 182.0 203.0 1110.0 2/0
NA2XSY 12/20kV 1×95 rm/16 24 5.5 2.5 31,0 – 36,0 182.0 276,0 1220.0 3/0
NA2XSY 12/20kV 1×120 RM/16 24 5.5 2.5 33,0 – 38,0 182.0 348.0 1310.0 4/0
NA2XSY 12/20kV 1×150 RM/16 24 5.5 2.5 34,0 – 39,0 182.0 435.0 1460.0 300 kcmil
NA2XSY 12/20kV 1×150 RM/25 24 5.5 2.5 34,0 – 39,0 283.0 435.0 1520.0 300 kcmil
NA2XSY 12/20kV 1×185 RM/16 24 5.5 2.5 36,0 – 41,0 182.0 537.0 1660.0 350 kcmil
NA2XSY 12/20kV 1×185 RM/25 24 5.5 2.5 36,0 – 41,0 283.0 537.0 1720.0 350 kcmil
NA2XSY 12/20kV 1×240 RM/25 24 5.5 2.5 39,0 – 44,0 283.0 696.0 1910.0 500 kcmil
NA2XSY 12/20kV 1×240 RM/16 24 5.5 2.5 39,0 – 44,0 182.0 696.0 1860.0 500 kcmil
NA2XSY 12/20kV 1×300 RM/25 24 5.5 2.5 41,0 – 46,0 283.0 870,0 2220.0 600 kcmil
NA2XSY 12/20kV 1×400 RM/35 24 5.5 2.5 44,0 – 49,0 394,0 1160.0 2620.0 750 kcmil
NA2XSY 12/20kV 1×500 RM/35 24 5.5 2.5 47,0 – 52,0 394,0 1450.0 3030.0 1000 kcmil
 
Description & No conducteurs x cross-sec. mm2, Tension nominale Tension de fonctionnement max. Isolée. D'ÉPAISSEUR-ness mm Veste-ness mm épais Extérieur
Dia. min.-max.
Poids de cuivre
Kg/km
Alu Poids kg/km Poids env. kg/km AWG
NA2XSY 18/30kV 1×50 rm/16 36 8.0 2.5 33,0 – 38,0 182.0 145,0 1260.0 1
NA2XSY 18/30kV 1×70 rm/16 36 8.0 2.5 35,0 – 40,0 182.0 203.0 1360.0 2/0
NA2XSY 18/30kV 1×95 rm/16 36 8.0 2.5 36,0 – 41,0 182.0 276,0 1510.0 3/0
NA2XSY 18/30kV 1×120 RM/16 36 8.0 2.5 38,0 – 43,0 182.0 348.0 1610.0 4/0
NA2XSY 18/30kV 1×150 RM/25 36 8.0 2.5 39,0 – 44,0 283.0 435.0 1810.0 300 kcmil
NA2XSY 18/30kV 1×150 RM/16 36 8.0 2.5 39,0 – 44,0 182.0 435.0 1760.0 300 kcmil
NA2XSY 18/30kV 1×185 RM/16 36 8.0 2.5 41,0 – 46,0 182.0 537.0 1960.0 350 kcmil
NA2XSY 18/30kV 1×185 RM/25 36 8.0 2.5 41,0 – 46,0 283.0 537.0 2020.0 350 kcmil
NA2XSY 18/30kV 1×240 RM/25 36 8.0 2.5 43,0 – 48,0 283.0 696.0 2260.0 500 kcmil
NA2XSY 18/30kV 1×240 RM/16 36 8.0 2.5 43,0 – 48,0 182.0 696.0 2210.0 500 kcmil
NA2XSY 18/30kV 1×300 RM/25 36 8.0 2.5 46,0 – 51,0 283.0 870,0 2560.0 600 kcmil
NA2XSY 18/30kV 1×400 RM/35 36 8.0 2.5 49,0 – 54,0 394,0 1160.0 2960.0 750 kcmil
NA2XSY 18/30kV 1×500 RM/35 36 8.0 2.6 52,0 – 57,0 394,0 1450.0 3460.0 1000 kcmil

    

 

L'emballage&livraison.
 

L'emballage en bois,Détails:fûts fûts en bois d'acier ou en tant que vos besoins
délai de livraison:normalement dans les 30 jours(detailly dépendent de la quantité de commande)

Contactez-nous
Hâte à la coopération avec.Si vous avez des questions ou besoin de notre certification et de sample.pls de me contacter librement.Vous pouvez parler avec moi par courriel ou logiciel de chat. Obtenir des prix au sein de 5 minutes
 

Qui nous sommes Chine Na2xs (Fl) 2Y 1X400/50 12/20 Kv câble HDPE d′étanchéité longitudinale fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.

Get Latest Price Request a quote

Popular Na2xs (Fl) 2Y Des produits

Na2xs (Fl) 2Y 12/20 kv 1x95/50mm2 Câble de PEHD d′étanchéité longitudinale

12/20kv 120 mm2 conducteurs en aluminium avec isolation XLPE Na2xs (Fl) 2câble en Y

12/20kv 120 mm2 conducteurs en aluminium avec isolation XLPE Na2xs (Fl) 2câble en Y

18/30kv conducteurs en aluminium simple coeur de blindage en fil de cuivre 240mm2 Na2xs (Fl) 2câble en Y

N2xs (FL) 2y/Na2xs (FL) 2y 12/20 kV RM 1X300/25 1X400/50mm2 Câble

Popular Na2xs (Fl) 2Y 1X400/50 12/20 kv Des produits

  • No related articles
  • Popular Na2xs (Fl) 2Y 1X400/50 12/20 Kv câble HDPE d′étanchéité longitudinale Des produits

  • No related articles
  • Popular zzhongdacable Des produits

    Isolation PVC conducteur 0.6/1kv Al et gaine PVC aluminium souterrain Câble d′alimentation 1-Ayky

    Les frais généraux de l'aluminium avec isolation XLPE ABC câble 2+1 Core Twisted Duplex Triplex Quadruplex multicore

    Fil TW THW 14AWG 12AWG 10AWG 8AWG THW-2 600V cuivre Norme UL

    L'aluminium Service de câble conducteur de ligne de chute de fil recto verso

    5 conducteurs 2,5 mm2 4mm2 6mm2 10mm2 16mm2 Câble PVC fil souple

    Polyéthylène Cross-Linked (XLPE) 6AWG SAE J-1127 Sgt Sgx Stx Câble de batterie

    Tags: , , ,

    SERVICE RAPIDE ET FIABLE POUR VOTRE PROJET

    Contactez nos experts qualifiés dès aujourd'hui pour trouver votre solution d'alimentation parfaite.

    POSER UNE QUESTION