Applicant:
Spacer Cable – Installed with other spacer cables and a supporting messenger through a series of space-maintainingdevices (spacers). The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation particularly useful in congested areas.
Cable structure:
Number of core: single core
Conductor: Compact stranded hard drawn aluminum wire conductor sizes 35mm2 up to 240mm2.
Conductor Shield: Semi conductor
Insulation: cross-linked polyethylene colour: Natural
Sheathed: Track resistant cross-linked polyethylene Colour: Black
Classification : Normal operation 90 C
Emergency overload conditions 130C
Short circuit conditions 250C
Voltage rating 35KV
Testing Voltage: 49KV for 5minutes
Reference: ICEA S-66-524
Tree wire (tree wire,Medium Voltage Covered Conductor) manufactured by HT meets or exceeds the requirements of all international standards like ASTM, AS, BS, CSA, DIN,IEC, NFC, SS -etc
Technical Data
11kV (15)kV 90°C SAC SPACED AERIAL CABLE
| NUMBER OF CORE | Single core |
| 1. CONDUCTOR |
|
| 2. CONDUCTOR SHIELD | Semi conducting cross-linked polyethylene |
| 3. INSULATION |
|
| 4. SHEATH |
|
| CLASSIFICATION |
|
| TESTING VOLTAGE | 27KV for 5 minutes |
| REFERENCE | ICEA S-66-524 / MEA |
| Nominal Sectional Area mm2 |
Minimum Number of wire NO |
Diameter of Conductor (approx.) mm |
Thickness of Insulation mm |
Thickness of sheath mm |
Overall Diameter (approx.) mm |
Maximum DC. conductor resistance at 20°C Ω / km |
Cable weight (approx.) kg / km |
| 35 | 7 | 6.95 | 1.91 | 1.91 | 16.1 | 0.8680 | 245 |
| 50 | 7 | 8.33 | 1.91 | 1.91 | 17.2 | 0.6410 | 295 |
| 70 | 18 | 9.73 | 1.91 | 1.91 | 18.9 | 0.4430 | 370 |
| 95 | 18 | 11.45 | 1.91 | 1.91 | 20.6 | 0.3200 | 465 |
| 120 | 18 | 12.95 | 1.91 | 1.91 | 22.0 | 0.2530 | 552 |
| 150 | 18 | 14.27 | 1.91 | 1.91 | 23.4 | 0.2060 | 646 |
| 185 | 34 | 15.98 | 1.91 | 1.91 | 25.1 | 0.1640 | 766 |
| 240 | 34 | 18.47 | 1.91 | 1.91 | 27.6 | 0.1250 | 955 |
25kv 90°C SAC SPACED AERIAL CABLE
| NUMBER OF CORE | Single core |
| 1. CONDUCTOR |
|
| 2. CONDUCTOR SHIELD | Semi conducting cross-linked polyethylene |
| 3. INSULATION |
|
| 4. SHEATH |
|
| CLASSIFICATION |
|
| TESTING VOLTAGE | 38KV for 5 minutes |
| REFERENCE | (TIS 2341-2555) |
| Nominal Sectional Area mm2 |
Minimum Number of wire NO |
Diameter of Conductor (approx.) mm |
Thickness of Insulation mm |
Thickness of sheath mm |
Overall Diameter (approx.) mm |
Maximum DC. conductor resistance at 20°C Ω / km |
Cable weight (approx.) kg / km |
| 25 | 7 | 5.90 | 3.18 | 3.18 | 20.0 | 1.2000 | 317 |
| 35 | 7 | 6.95 | 3.18 | 3.18 | 21.0 | 0.8680 | 390 |
| 50 | 7 | 8.33 | 3.18 | 3.18 | 22.0 | 0.6410 | 440 |
| 70 | 18 | 9.73 | 3.18 | 3.18 | 24.5 | 0.4430 | 540 |
| 95 | 18 | 11.45 | 3.18 | 3.18 | 26.0 | 0.3200 | 640 |
| 120 | 18 | 12.95 | 3.18 | 3.18 | 27.0 | 0.2530 | 740 |
| 150 | 18 | 14.27 | 3.18 | 3.18 | 29.5 | 0.2060 | 850 |
| 185 | 34 | 15.98 | 3.18 | 3.18 | 31.0 | 0.1640 | 990 |
| 240 | 34 | 18.47 | 3.18 | 3.18 | 33.5 | 0.1250 | 1,190 |
33kv (35) kv 90°C SAC SPACED AERIAL CABLE
| NUMBER OF CORE | Single core |
| CONDUCTOR |
|
| CONDUCTOR SHIELD | Semi conducting cross-linked polyethylene |
| INSULATION |
|
| SHEATH |
|
| CLASSIFICATION |
|
| TESTING VOLTAGE | 49KV for 5 minutes |
| REFERENCE | (TIS 2341-2555) |
| Nominal Sectional Area mm2 |
Minimum Number of wire NO |
Diameter of Conductor (approx.) mm |
Thickness of Insulation mm |
Thickness of sheath mm |
Overall Diameter (approx.) mm |
Maximum DC. conductor resistance at 20°C Ω / km |
Cable weight (approx.) kg / km |
| 25 | 6 | 5.90 | 4.45 | 3.18 | 22.5 | 1.2000 | 393 |
| 35 | 6 | 6.95 | 4.45 | 3.18 | 24.5 | 0.8680 | 443 |
| 50 | 6 | 8.33 | 4.45 | 3.18 | 25.5 | 0.6410 | 517 |
| 70 | 12 | 9.73 | 4.45 | 3.18 | 27.5 | 0.4430 | 599 |
| 95 | 15 | 11.45 | 4.45 | 3.18 | 29.0 | 0.3200 | 711 |
| 120 | 15 | 12.95 | 4.45 | 3.18 | 31.0 | 0.2530 | 831 |
| 150 | 15 | 14.27 | 4.45 | 3.18 | 32.5 | 0.2060 | 933 |
| 185 | 30 | 15.98 | 4.45 | 3.18 | 33.5 | 0.1640 | 1,073 |
| 240 | 30 | 18.47 | 4.45 | 3.18 | 36.5 | 0.1250 | 1,293 |
Please check the specification, Our competitive price will send you in 12 hours. we can customize other cross-sections on request.
Packaging&Delivery
Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 10 days (detailly depend on the order quantity)
Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.
Tel :+86 15039132763
Qui nous sommes Chine Sac 1X240mm2 Al/XLPE/HDPE Spaced Aerial Cable 11kv Overhead Line fabrication et fournisseur,Vous pouvez obtenir plus de détails par e-mail, vous obtiendrez un prix bon marché ou un prix usine.
Get Latest Price Request a quote
Popular Sac 1X240mm2 Al/XLPE/HDPE Spaced Aerial Cable 11kv Overhead Line Des produits
Popular Sac Cable 1X240mm2 Des produits
Popular Spaced Aerial Cable Des produits
Popular zzhongdacable Des produits
Câble électrique plat 2X2.5+1.0mm 3 Core 2+e câble d'alimentation solide fil plat
2-2-2 Conch câble de branchement de conducteur de pavillon triplex en aluminium
BS6004 Câble d'alimentation à double isolation 6381y pour les alimentations
Tags: Sac 1X240mm2 Al/XLPE/HDPE Spaced Aerial Cable 11kv Overhead Line, Sac Cable 1X240mm2, Spaced Aerial Cable, zzhongdacable